TS2000 (V2+) INTRUDER ALARMCONTROL SYSTEMUSER MANUAL
(a) When momentarily activated during Setting, after use of the Last Exit, willcomplete the Setting process if it has been programmed to do so (para 3
The System Activated Outputs may be allocated to any Node (NU or REM) output or thePanel (CP) outputs. They are designated by their function and may b
(6) Exit: The relevant Ward (with WCU) exit procedure has been initiated (para 3.3);(7) Entry: The relevant Ward (with WCU) entry procedure has been i
Second Entry Time: Is an additional period of time allowed for entering protectedpremises that is activated after the First Entry Time has expired dur
(8) Re-arm: This may be set to Auto or to Manual. Auto Re-arm means that at the end ofthe Bell Duration period the circuit will repeat the alarm, if t
3 SYSTEM MENUS3.1 IntroductionA series of Menus are provided which determine all the actions that may be taken toprogramme or control the system. Ther
3.4 Unsetting the System3.4.1 The System may be unset in a number of ways:(1) Entry Procedure: This is normally initiated by using the access designat
The omitted circuits will be automatically enabled when the system or relevant ward is unsetunless the ward is key controlled.3.11 Use Chime Facility
used to enable Panel or Node outputs (para 2.6) at the times set and there is a manualoverride facility.3.17 Alter Time Lock (Menu 14)The Time Lock is
(11) Double Knock time: time period of double knock window;(12) Line Fault d: delay before line fault alarm.3.23 Define Panel Modes (Menu 20)The syste
TS2000 (V2+) User ManualCOPYRIGHTAll rights reserved. No part of the information contained in this publication may be reproduced or copied byany means
this will be indicated by changing the end of line links at the old end unit and the newunit, also the system will not need to re-number all units, ci
Issue 02 Feb 92TS2000 (V2+) User ManualPage 3 - 7Menu No Menu Level Ref Para1 Start Set Sequence 1, 2, 3, 4, 5, 6 432; 4332 Unset Wards 1, 2, 3, 4, 5,
Issue 02 Feb 92 Page 4 - 1TS2000 (V2+) User Manual4 OPERATING THE SYSTEM4.1 Introduction4.1.1 The system is controlled from a REM by using the keypad
Issue 02 Feb 92 Page 4-2TS2000 (V2+) User Manual4.2 Set System and all Available Wards (without WCU). Circuits may be OmittedSTEP ACTION DISPLAY REMAR
Issue 02 Feb 92 Page 4-3TS2000 (V2+) User Manual4.4 Set System and Some or No Wards (without WCU). Circuits may be OmittedSTEP ACTION DISPLAY REMARKS1
Issue 02 Feb 92 Page 4-4TS2000 (V2+) User Manual4.6 Set System and Some or No Wards with Wards Previously Set (no WCU) and No Circuits OmittedSTEP ACT
Issue 02 Feb 92 Page 4-5TS2000 (V2+) User Manual4.9 Set More Wards with Wards Previously Set (no WCU) and With Circuits OmittedSTEP ACTION DISPLAY REM
Issue 02 Feb 92 Page 4-6TS2000 (V2+) User Manual4.11 Unset Wards with Circuits OmittedSTEP ACTION DISPLAY REMARKS1 - SET- 1 (to) 8(date) (time)System
Issue 02 Feb 92 Page 4-7TS2000 (V2+) User Manual4.13 Clearing Circuits OmittedSTEP ACTION DISPLAY REMARKS1 - CIRCUITS OMITTED(date) (time)Circuit or c
Issue 02 Feb 92 Page 5 - 1TS2000 (V2+) User Manual5 PROGRAMMING THE SYSTEM5.1 Introduction5.1.1 The system is initially programmed by an Engineer duri
TS2000 (V2+) User ManualCONTENTS1 OVERVIEW1.1 Introduction Page 1-11.2 Equipment Page 1-11.3 Control Panel Options Page 1-11.4 Additional Equipments P
Issue 02 Feb 92 Page 5 - 2TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 No* Press <YES> toVIEW CIRCUITSPress YES to View Circuits. Press
Issue 02 Feb 92 Page 5 - 3TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 No* Press <YES> toSELECT BELL TESTPress YES to carry out Bell Tes
Issue 02 Feb 92 Page 5 - 4TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 No* Press <YES> toUSE CHIME FACILITYPress YES to use Chime Facili
Issue 02 Feb 92 Page 5 - 5TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toUSE THE PRINTERPress YES to use the Printer. Pr
Issue 02 Feb 92 Page 5 - 6TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toALTER CLOCKPress YES to set system date and tim
Issue 02 Feb 92 Page 5 - 7TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toDEFINE USERSPress YES to Define Users. Press NO
Issue 02 Feb 92 Page 5 - 8TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS13 (1234) Code confirmed OKPress any keyPress any key14 YES ALTER PASSCOD
Issue 02 Feb 92 Page 5 - 9TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toALTER TIME SWITCHPress YES to alter Time Switch
Issue 02 Feb 92 Page 5 - 10TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toALTER TIME LOCKPress YES to alter Time Lock. P
Issue 02 Feb 92 Page 5 - 11TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 Eng Passcode* Press <YES> toDEFINE CIRCUITSPress YES to Define C
TS2000 (V2+) User Manual4 OPERATING THE SYSTEM4.1 Introduction Page 4-14.2 Set System & all AvailableWards (w/o WCU)Page 4-24.3 Set System without
Issue 02 Feb 92 Page 5 - 12TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO** Press <YES> toDEFINE OUTPUTSPress YES to Define Outputs. Pr
Issue 02 Feb 92 Page 5 - 13TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toDEFINE WARD ALARMSPress YES to define Ward Ala
Issue 02 Feb 92 Page 5 - 14TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toDEFINE PANEL MODESPress YES to Define Panel Mo
Issue 02 Feb 92 Page 5 - 15TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toUSE TEST OPTIONSPress YES to use Test Facilite
Issue 02 Feb 92 Page 5 - 16TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toUSE NETWORK OPTIONSPress YES to use Network Op
Issue 02 Feb 92 Page 5 - 17TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toDEFINE CIRCUIT TEXTPress YES to Define Circuit
Issue 02 Feb 92 Page 5 - 18TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS1 NO* Press <YES> toINSTALL DC3Press YES to program Digital Commun
Issue 02 Feb 92 Page 5 - 19TS2000 (V2+) User Manual
Issue 02 Feb 92 Page 5 - 20TS2000 (V2+) User ManualSTEP ACTION DISPLAY REMARKS19 YES PLEASE WAIT Loading Modem data20 MODEM NO000000000000000000**Old
INTRUDER ALARM CONTROL SYSTEM TS2000 (S/W V2+)1 OVERVIEW1.1 IntroductionThe Intruder Alarm Control System TS2000 is provided for large domestic and ge
(4) Modem type DC3M (Digimodem): Will transfer data over PSTN lines to and from anysuitable equipment such as a computer terminal. When activated the
Issue 02 Feb 92TS2000 (V2+) User ManualPage 1 - 3* = OptionCONTROLPANELNodeorRemote KeypadNo 1NodeorRemote KeypadNo XRemotePowerSupply Unit*Other Opti
2 OPERATIONAL FACILITIES2.1 Introduction2.1.1 The system operates in two states which may be considered as 'Monitoring', when thesystem resp
(2) Master;(3) Manager;(4) Standard S (system);(5) Standard W (ward);(6) Restricted;(7) Not Used;The highest level is (1) and the lowest is (6) so tha