5. SD1+ Connections
Before any connections are made to the SD1+ re move the power (battery and 240V
mains) from the control panel. Connections are provided as follows:
ABOR T: When triggered, the SD1+will a bort the dialling sequence.
TRIG A: When triggered, the unit starts the dialling sequence and sends
message A.
TRIG B: When triggered, the unit starts the dialling sequence and sends
message B.
TRIG C: When triggered, the unit starts the dialling sequence and sends
message C.
Tri gger/Abort inputs can be selected to be either +ve applied to
triggeror-ve appliedto trigger.Set the "Trigger Polarity"jumper-link to
the appropriate positi on. The figure below shows the dif ferent types of
output t ypes t hat can be connected to the SD1+.
BOX TAMPER: Th ese two terminals can be conn ected to the m ain tamper zone on
the alarm co ntrol panel, to provi de case tamper protection for the
SD1+.
0V: Connect to a permanent 0V supply on the control panel.
+12V: Connec t to a permanent +12V supply on the control panel.
O/P1: A switched -v e programmable output.
+
ConnectionsontheSD1+ aredescribed asether"SafetyExtra-Low Voltage"circuits(SELV)or
"Telecommunication Network Voltages" cir cuits (TNV). Therefor e it is important t hat installer
ensures that TNV circuits are only connected to the P STN and SELV circuits are only
connected to other circui ts designated as SELV circuits.
+
Please ensure that cabling to the telephone line connections (TNV) are routed well away
from the trigger input circuitry (SELV) and the cabling to the tr igger input circuitry (SELV) are
routed well away from the telephone circuitry (TNV ).
SD1 SD1
+12V +12V
TRI G POLAR ITY TRI G POLAR ITY
0V 0V
+ +
- -
TRI G A TRI G A
TRI G B TRI G B
TRI G C TRI G C
12V on alarm 0V on alarm
1K
resistor
1K
resistor
N.C.
Loop
N.O.
Loop
N.O.
Loop
N.C.
Loop
TRIG A = Normally Closed Input
TRIG B = Normally Open Input
TRIG C = Switched +ve Input
TRIG A = Normally Open Input
TRIG B = Normally Closed Input
TRIG C = Switched -ve Input
6. Control Panel Connec tions
Th e table below shows the connection details to various control panels.
Control Panel TRI G A
Fire
TRI G B
PA
TRI G C
Alarm
Polarity Supply + Supply - Trigger
Type
Menvier TS400/TS410 Zo ne 4 Zone 5 ALM - Aux + Aux - 0V app.
Menvier TS510 N/A OP 2 * OP 1 * - Aux + Aux - 0V app.
Menvier TS690R OP 1 OP 2 OP 3 - Aux + Aux - 0V app.
Menvier TS690/TS700 Digi 1 Digi 2 Di gi 3 - Aux + Aux - 0V app.
Menvier TS790/TS900/TS2500 Digi 1 Digi 2 Digi 3 - Aux+ Aux - 0V app.
A1 Advantage N/A N/A Bell - - Aux + Aux - 0V app.
ADE Optima XM N/A N/A B - 13V + 13V - 0V app.
ADE Optima 2+ Fire PA Intruder - 13V + 13V - 0V app.
ADE Concept 6 N/A N/A B - 13V + 13V - 0V app.
ADE Acce nta 6 N/A N/A B - 13V + 13V - 0V app.
Ademco Infra 6 N/A N/A 3 + Aux + Aux - 12V app.
Ademco Infra 16 1* 2 3 + A ux + Aux - 12V app.
C & K 700L N/A N/A S- - Aux + Aux - 0V app.
CQR Premia 9 FA * PA IA + Aux 12V Aux 0V 12V app.
DA Abacus 6 N/A N/A Bell - +12V 0V 0V app.
DA Abacus 8 N/A N/A Bell - +12V 0V 0V app.
Gardtec 500 Se ries N/A N/A Bell - - Power + Power - 0V app.
Gardtec 800 Se ries D1 * PA 12Hr - 12V 0V 0V app .
JSB Regent COM1 COM2 COM3 + 12 V 0V 12V app.
Pyronix Paragon + /E N/A N/A BA - Aux + Aux - 0V app.
Pyronix Octagon N/A PA ALM - Aux + Aux - 0V app.
Pyronix Conqueror N/A N/A BA - Aux + Aux - 0V app.
Scantronic 9448 N/A COM 2 COM 3 - 12V 0 V 5V rem.
Scantronic 9452/3 N/A COM 1 COM 3 - Aux 12V Aux 0V 5V rem.
Scantronic 9454 N/A COM 1 COM 3 - 12V 0 V 5V rem.
Scantronic 9455 N/A COM 1 COM 3 - 12V 0 V 5V rem.
Texecom Veritas R8 N/A N/A B - Aux + Aux - 0V app.
TexecomVeritas8 Compact N/A N/A B - Aux + A ux - 0V app.
* Cont rol panel output requires p rogramming.
+
When using the bell output to trigger the SD1+, you may find that the external sounder is
partially tri ggered . If this is the case a 1K resistor will need to be connected between the
SD1+ trigger input and +12V.