Chime Circuits
This option allows an alternative method of
programming circuits as “chime”.
Alter 24Hr Group
Circuit types 24hr and Auxiliary with the
"Omittable" attribute can be assigned to the 24hr
group. The 24hr group is isolated by using user
menu 1 option 6, see "User Manual".
Print System Log
The system log stores 700 events (1800 when
expanded), if a printer is connected to the system
it is possible to print a selected number of events.
Once the print-out has been started it can only be
stopped by selected this option again and
entering "000" for the number of events.
Configure Wards
The TS790 and TS900 can be split into four wards
(areas):
System Ward
Wards A
Ward B
Ward C
Each ward can then be assigned to passcodes or
part-set buttons to allow flexible part-set
arrangements. See “Part Set Groups” on page 43
and “Code Set Groups” on page 43.
Only “Night”, “Final Exit” and “Exit terminator” circuit
typescan beassignedtowardsA,BandC.Circuits
can be assigned to more than one ward (A,B or C)
thus creating overlapping areas. Circuits that are
assigned to more than one ward will only be
armed when both or all wards are set.
From the factory, all detection circuits are
assigned to the system ward (i.e., they are not
assigned to wards A, B or C). Circuits that remain
assigned to the system ward can also be set or
unset independently.
Alter Chime ccts
Enter CCT No.>--
Font Door
CCT 10 Silent
Circuit No &
Status
Enter circuit No.
e.g. 10
Circuit text
= Next Circuit
5
ESC
A
= Alternate Chime/Silent
B
= Previous Circuit
C
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
01-S
CCT 01-S
10-S
CCT 10-S
Chime Circuits Flowchart
Alter 24Hr Group
Enter CCT No.>--
Roller Door
CCT 09 Omitted
Circuit No. &
Status
Enter circuit No.
e.g. 09
Circuit text
= Next Circuit
6
ESC
A
= Alternate Armed/Omitted
B
= Previous Circuit
C
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
01-A
CCT 01-A
09-O
CCT 09-O
Alter 24hr Group Flowchart
Print System Log
No. events> ---
Print System Log
No. events> 100
Enter number of events
e.g. 100
to start printing
7
ENT
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2-
ENGR 2 -
---
---
100
100
Print System Log Flowchart
TS900 Installation Manual Engineer's Menu 2
37