TECHNICAL BULLETIN
CPA6/001/08/96
CPA6 MKII & ACPO POLICY
There seems to be some confusion as to whether the CPA6.MKII can comply with the new ACOP policy. This is
because the SET output de-activates on starting entry procedure on most versions of CPA6 MKII software.
However software version STD2.21 has a correctly operating SET output and also RESTORES the Alarm output
on UNSET (alarm Abort)
STD2.21 software can be fitted to the CPA6 MKII providing that the memory board has 2 memory chip sockets
(1x28 pin and 1x24 pin). Although the upgrading of chips should be fairly strait forward the system will require
full reprogramming.
Software version STD2.21 is available as an upgrade item from the repairs department and any enquires as to
the availability or prices should be obtained through them.