Final Exit
This is the point at which the user leaves and enters the premises (normally the front door).
When setting the system the user must leave the premises via the exit route and through
the Final Exit zone. When re-entering the premises the user must activate the Final Exit zone
to start the entry timer which allows the user time to gain access to the control panel to
unset the system. If the user enters the premises through any other point and triggers a
detection device a full alarm will be generated.
The system may be programmed to set after the exit timer has expired or by the operation
of the Final Exit detection device.
Keyswitch
An optional keyswitch may be fitted to the system to allow the user to set and unset (or
part-set and unset) the system using a physical key rather than a four digit passcode.
Power Supply Considerations
The maximum current available from the control panel power supply is 750mA. The total
current consumption of all devices (Panel, detectors, sounders, strobes battery charge
etc.) that are connected to the system must not exceed 750mA.
The following is a typical example on how the total current is calculated. When calculating
the total current for your own installation refer to the manufacturers specifications on each
device.
Total available current from control panel = 750mA
Control panel = 80mA
+
External Sounder = 250mA
+
External Strobe = 120mA
Total Current = 450mA
Auxiliary Current = 300mA (750 -450)
From the above calculation example there is 300mA available for powering detection
devices etc.
System Planning TSD402 Installation Manual
8