1 Y=User 1 limited in menu 2
N=User 1 not limited in menu 2
2 Y=Fire signalled in unset/partset
N=Fire not signalled in unset/partset
3 Y=24hr ccts silent in unset
N=24hr ccts audible in unset
4 Y=Bell instant in partset
N=Bell delayed in partset
5 Y=Alarm output cleared when unset
N=Alarm output not cleared
6 Y=Setting inhibited with LF/no AC
N=Setting OK with LF/no AC
7 Y=User Reset
N=Engineer Reset
8 Y=Constant Exit tone
N=Rising Exit tone
9 Y=Eng Code + Reset code for access
N=Eng Code for access
0 Y=Bell is an SAB type
N= Bell is an SCB type
PANEL OUPUTS
1
DIGI OUTPUTS
2
DIGI CHANNELS
3
PROGRAM
CIRCUITS
4
SYSTEM TIMERS
5
POWER
SETTING MODES
6
SYSTEM PRINT
7
ALGORITHM NO
8
CONFIGURATION
9
En
er eng
neer passco
e
(Default 1234)
E1 -
Press key to select option
OUPUT TYPES
00 Bell On
01 Strobe
02 SW12V
03 Viper Reset
04 Walk Test
05 Alarm
06 P.A.
07 Fire
08 Set
09 Code Valid
10 24hr
11 2nd Alarm
12 Courtesy Light
13 Eng on Site
14 Circuits Omitted
15 Auxiliary
16 Sounder control
17 Part Set A
18 Part Set B
19 Part Set C
20 Circuit Tamper
21 Line Fault
22 AC Off
23 Exit / Entry
24 Test Fail
25 First Knock
26 DC Failed
27 DC Successful
28 DC Active
29 2nd Entry
30 Entry
31 Exit
32 Part Set C fail
33 Part Set B fail
34 Part Set A fail
35 Part set
36 Area C Alarm
37 Area B Alarm
38 Area A Alarm
39 Duress Alarm
40 - 55 Circuit Mimics 1-16
CIRCUIT TYPES
1 Night
2 24 hr
3 P.A. Silent
4 P.A. Audible
5 Fire
6 Aux
7 Final Exit
8 Exit Terminator
9 Full Set Key
0 Not used
A Part Set Key A
B Part Set Key B
C Part Set Key C
ATTRIBUTES
1 Access
2 Double Knock
3 Test
4 Isolatable
5 Reset
1 No of Re-Arms
2 Settling Time
3 Digicom Delay
4 Exit Time
5 Entry Time
6 Bell Duration
7 Bell Delay Time
8 Double Knock Time
9 Test Time
0 Acpo Delay Time
TIMER OPTIONS
SETTING MODES Press ESC to stop Enter number CONFIGURATION
0 Full Set
A Part Set A
B Part Set B
C Part Set C
ATTRIBUTES
1 Final Exit
2 Exit Terminator
3 Timed Exit
0 "Toggle"
Quick Reference Guide
VIEW CIRCUITS
1
SET CLOCK
2
SET DATE
3
ENGINEER
PASSCODE
4
CONFIGURE CHIME
5
POWER
CONFIGURE 24 HR
OMIT GROUP
6
PRINT SYSTEM LOG
7
CONFIGURE
PART-SET GROUPS
8
VIEW SYSTEM LOG
9
From E1 - press [
Press key to select option
RESET MASTER
USER
0
ENGINEER MENU 1
]
Engineer Menu 2
Engineer Menu 1
RETURNING TO UNSET
1. From E1 - press ].
2. The display will show `ENG. ON SITE'.
3. This message is cleared by entering a valid user passcode.
SELECTING USER MENU 1
1. From E1 - press 0.
2. The display will show `1 -'.
3. Refer to `User Operating Instructions' for full details.
..
.
..
..
. . . .....
.
.
Tir.-
CT.--Dc3.-
DIG.-
PAN.- S.BY-
Ln01
004
con.-
E2 -
E2 -
.
.
01-N--------
----
01-H
01-A
---
PS. -
Ur.00
E1 -