Installing Remote Keypads and LECs
The following types of devices may be connected to the control panel:
NETLED - 4 x 7 Segment LED display.
NETSTAR - 8 C haracter Starb urst LCD dis play.
NETARM - Remote Arming st ation (Power LED & programmable "Function" LED).
TS700.LEC - 2 zone local expansion card.
Any combination of devices can be used on the same system, providing the total number does
not exceed four.
1. Alwaysensurethatallpower(mainsandbattery)is removed befor e makinganyconnections
to the remote keypad.
2. Separate the cover and base by us ing a screwdriver to push 2 of the clips (top or bottom)
inward from the base indents, then lift the cover a ssembly, noting thatth e PCB is fixed t o the
under side of the cover.
3. Holdthebaseinposition (keyholetothe top)andmarkthethree securingholes, drilla ndplug
the wall as required. Pass all the cables int o the base via th e cable entry points as
appropriate and secure the base to the wall.
4. Connect “Remote Network” and detection circuit cables to the approp riate t ermi nals, see
Figure 4.
5. Set the I/D selector jumper link to the required position:
I/D Selector Circuit A Circuit B Panel Output
1 09 10 5
2 11 12 6
3 13 14 7
4 15 16 8
ENG / NU LL N/A N/A N/A
☞
No two remote keypads or LECs shou ld have the same I/D.
☞
If the I/D is set to “ENG” the remote keypad will function as an Engineer’s keypad
allowing it to be plugged onto the control panel so that system programming and
testing may be carried out (see Engineer’s Keypad).
6. Fordetailson a llremote keypadoption links, please r efer to the instructionssupplied withthe
remote keypad.
7. Finally cliptheremote ke ypad cover ontothe base being carefulnott o trapanycables or to
obstruct the tamper switch.
Engineer's Keypad
Normally a ll system programming will be carried out from one of the installed remote keypads.
However sometimes it may be more convenient to program the system at the control panel, this
can be achieved by using an Engineers Keypad. This is temporarily plugged on to the control
panel (JP2). To convert a standard remote keypad to an "Engineers Keypad" an interface lead
can be obtained from your supplier (P/No. NETEKI).