Tamper Switch.
Remote Keypad case tamper
ENT Key Disable.
If the “ENT” key is enabled the remote keypad can
be used to set/unset and access all user menus. If
the “ENT” key is disabled the remote keypad can
only be used to set and unset the system.
Installation Procedure.
Always ensure that all power (mains
and battery) is removed before
making any connections to the
remote keypad.
1. Separate the cover and base by using a
screwdriver to push 2 of the clips (top or
bottom) inward from the base indents, then lift
the cover assembly, noting that the PCB is fixed
to the under side of the cover.
2. Hold the base in position (keyhole to the top)
and mark the three securing holes, drill and
plug the wall as required. Pass all the cables
into the base via the cable entry points as
appropriate and secure the base to the wall.
3. Connect “Remote Network” and detection
circuit cables to the appropriate terminals, see
Figure 8.
4. Set the I/D selector jumper link to the required
position:
I/D Selector Circuit A Circuit B
Panel
Output
109105
211126
313147
415168
ENG/NULL N/A N/A N/A
l
No two remote keypads or LECs should
have the same I/D.
l
If the I/D is set to “ENG” the remote keypad
will function as an Engineer’s keypad
allowing it to be plugged onto the control
panel so that system programming and
testing may be carried out (see Engineer’s
Keypad).
5. If the remote keypad has a "ENT" key
enabled/disable link it can be used to limit the
functionality of the remote keypad. If the "ENT"
key is enabled the remote keypad can be
used to set/unset and access all user menus. If
the "ENT" key is disabled the remote keypad
can only be used to set and unset the system.
6. If the remote keypad has a “Ward Sounder
Control” link it can be used to make the remote
keypad sounder follow the programmable
output. When the link is set to the disabled
position the sounder responds as normal.
9
TS790 & TS900 Installation Manual System Installation
I/D
Selector
REMOTE
I/D
LED MIMIC
ENT KEY
DISABLED
1
2
3
4
ENG
WARD SOUNDER
CONTROL
ABCDE
SPK
+
1 2
3
5
4
67
89
Display Module
O/P
-
Figure 8. NETLCD, NETLED & NETARM PCB Layout
I/D
Selector
REMOTE
I/D
LED MIMIC
ENT KEY
DISABLED
1
2
3
4
ENG
WARD SOUNDER
CONTROL
4
5
Display Module
3
1
89
7
ABCDE
O/P
-
Figure 9. NETSTAR PCB Layout
Kommentare zu diesen Handbüchern