Location Text
This option allows the engineer to program a 32
character location message. When “Engineers
menu 1" is selected the engineer can view this
message. This can be used to provide the location
details for the control panel, e.g., ”C P located in
reception area", thus assisting service engineers
unfamiliar with the site.
Printer Header
This option allows the installation engineer to
program a 32 character printer header message.
This is printed whenever a system or log printout is
taken from the system. This can be used as a site
reference, e.g., “ABC Company Job No123456".
Part Set Banner
The part set banner is a 16 character message
displayed on the top line of the display whenever
the system is part set. If the message is left blank
the top line of the display will show the wards that
are set. If the message is programmed the top line
of the display will show the message, e.g., “System
Part-Set”.
Node Outputs
This option allows the engineer to program the two
outputs on each Node. Each output can be
programmed to any of the output types shown on
page 22.
Built In Tests
The TS790/TS900 system has the following
diagnostic routines:
Current Consumption
When this test option is selected the total current
consumption for the system is displayed, the
accuracy of this measurement is ± 50mA.
45
TS790 & TS900 Installation Manual Engineers Menu 3
Custom Text Menu
Select Option :-
7
ENT
Engineers menu 3
Select Option :-
= Reset Message
1
CALL ENGINEER TO
^ RESET SYSTEM
Usekeystoedittext
Cursor
= Banner Message
2
= Pannel Location Text
3
= Printer Header Text
4
= Part Set Banner
e.g. 1 for Reset Message
5
Custom Text Menu
Node Output ?
Enter Number > -
Node Output 1
is type > 004
Node Output 1
is type > 005
Enter new output type
Type No.
8
Enter output No. 0 - 9
e.g. 1
(Note: use 0 or output 10)
ENT
e.g. 021
Engineers menu 3
Select Options :-
StarburstLCD
LED
E3 -
ENGR 3 -
NoD.-
NODE OP -
004
004
005
005
Node Outputs Flowchart
Current 0568 mA
Current
1
ESC
Built In Tests
Select Option :-
Engineers menu 3
Select Option :-
9
StarburstLCD
LED
E3 -
ENGR 3 -
B.I.T -
TESTS -
0568
0568
System Current Flowchart