Custom Outputs A & B
These options allows the engineer to program
both custom outputs. The diagram below
represents the logic circuit for the custom output.
Each switch in the diagram represents a
programmable output type, therefore the custom
output will only activate when the correct
combination of output types are active.
Switches 1 - 4 perform a logical “OR” function and
switches 5 - 8 perform a logical “AND” function.
Custom Output - Example 1
This example shows how the “OR” function can be
used so that the “Custom Output” activates when
circuit 0001 or 0005 or 0016 causes an alarm
condition. The table below shows how each switch
is programmed to achieve this.
OR AND
1 Circuit 001 Alarm 5 Always Off
2 Circuit 0005 Alarm 6 Always Off
3 Circuit 016 Alarm 7 Always Off
4 Always Off 8 Always Off
When using the “Custom Output” for “OR”
logic only, all unused switches must be
programmed to the type “Always Off”.
Custom Output - Example 2
This example shows how the “AND” function can
be used so that the “Custom Output” only
activates when the system is ward A is set and time
switch A is active. The table below shows how each
switch is programmed to achieve this.
OR AND
1 Always Off 5 Ward A Set
2 Always Off 6 Time Switch A
3 Always Off 7 Time Switch A
4 Always Off 8 Time Switch A
When using the “Custom Output” for “AND”
logic only, switches 1-4 must be
programmed to the type “Always Off” and
any of the unused “AND” switches must be
programmed to the same type as one of
the used switches.
Custom Output - Example 3
This example shows how to use both the “AND” and
“OR” functions so that the “Custom Output”
activates when ward A is set and time switch A is
active or when the courtesy light output is active.
The table below shows how each switch is
programmed to achieve this.
OR AND
1 Courtesy Light 5 Ward A Set
2 Always Off 6 Time Switch A
3 Always Off 7 Time Switch A
4 Always Off 8 Time Switch A
When using the “Custom Output” for “AND”
and “OR” logic, any of the unused “OR”
switches must be programmed to the type
“Always Off” and any of the unused “AND”
switches (5-8) must be programmed to the
same type as one of the used switches.
47
TS790 & TS900 Installation Manual Engineers Menu 3
Custom O/P A,?
Enter Number > -
Custom O/P A,1
is type > 055
Custom O/P A,1
is type > 021
Enter new output type
Type No.
Enter switch No. 1 - 8
e.g. 1
ENT
e.g. 021
Engineers menu 3
Select Option :-
A
= Custom Output A
B
= Custom Output B
StarburstLCD
LED
E3 -
ENGR 3 -
CO.A-
CUSTOM.A-
055
055
021
021
Custom Outputs Flowchart
1
2
3
4
6 7
8
5
Custom
Output A
(048)
Input