Silent Set - 8
This menu option allows the user to full set or part-set the system silently whilst "User menu 1" is
selected. This is an alternative procedure to the one described on page 10.
1. Ensure that "User menu 1" is selected.
Press 8 to select the Silent Set option. The
display will show:
2. The system can now be full or part-set
silently by pressing:
0 for full set
A for part-set A
B for part-set B
C for part-set C
e.g., To full set the system, press "0" and
leave via the prescribed exit route. The
display will show:
View Activity Count - 9
Detection circuits that have been programmed by the installation company as "Flagged" will
increase the activity counter by one each time the circuit is activated when the system is unset.
The counter is automatically reset to zero when the system is full or part-set and the counter is
re-started when the system is unset. This counter could be used to count the number of persons
entering in to a particular area, e.g. shop entrance door. To view the counter proceed as
follows:
1. Ensure that "User menu 1" is selected.
Press 9 to select the View Activity Count
option. The display shows the count value
e.g.,
2. Press ] to abandon this option and
return to "User menu 1".
Full Set and Part-set - 0 A B C
This menu option allows the user to full or part-set the system from "User menu 1" as follows:
1. Ensure that "User menu 1" is selected.
The system can now be full or part-set by
pressing:
0 for full set
A for part-set A
B for part-set B
C for part-set C
e.g., To full set the system, press "0" and
leave via the prescribed exit route. The
display will show:
22
User Menu 1 TS790+ & TS900+ User Manual
SILENT -
SIL-
Silent Set ?
Enter Group >-
9999
9999
Please Exit Now.
Time left > 9999
0000
0000
Activity = 0000
Press ESC to end
9999
9999
Please Exit Now.
Time left > 9999
Kommentare zu diesen Handbüchern