Configure Wards - 8
The TS790+ & TS900+ can be split into four wards:
»
System Ward (S)
»
Ward A
»
Ward B
»
Ward C
Each ward can then be assigned to a passcode or part-set button to allow flexible part-set
arrangements. See “Part Set Groups” on page 39 and “Code Set Groups” on page 40.
Only “Night”, “Final Exit” and “Exit terminator” circuit types can be assigned to wards A, B and C. All
other circuit types must remain in the system Ward. Circuits can be assigned to more than one
ward (System, A, B or C) thus creating overlapping areas. Circuits that are assigned to more than
one ward will only be armed when both or all wards are set. Note that this may mean that a user
who sets one ward may not realise that some circuits are unset because they are shared with
another unset ward, for example the system ward.
From the factory, all detection circuits are assigned to the system ward (i.e., they are not
assigned to wards A, B or C). Circuits that remain assigned to the system ward can also be set or
unset independently. See “Part Set Groups” on page 39 and “Code Set Groups” on page 40.
1. Ensure that “User menu 2" is selected.
Press 8 to select the Configure Wards
option. The display will show:
2. Enter the circuit number, e.g., for circuit
02 enter “02". The top line of the display
shows the circuit text (if programmed) and
the bottom line shows the wards that the
circuit are assigned to e.g.:
Note that if you do not press any keys
then after 5s the display changes to
show the first zone.
3. Select/de-select the wards by pressing:
A for “Ward A”
B for “Ward B”
C for “Ward C”
e.g., press “A” then “B” to assign circuit
02 to wards A and B. If a low tone is
generated when pressing the “A”, “B” or
“C”, then the selected circuit cannot
be programmed into wards.
4. Press [ to accept and repeat from step
2 for other circuits, when finished press ] to
abandon this option and return “User
menu 2".
30
User Menu 2 TS790+ & TS900+ User Manual
Store Room PIR
CCT 02 in [AB ]
CCT 02-A
02-A
Configure Wards
Enter CCT No.>- -
CCT 01-
01-
Store Room PIR
CCT 02 in [ ]
CCT 02-
02-
CCT 02-B
02-B