Setup Users (Cont.)
Set Only
-
Users 02-31 may be programmed as "Set Only". This user type allows
the alarm system to be set and access to "User menu 1".
Reset Only
-
Users 02-31 may be programmed as "Reset Only". This user type allows
24hr alarms to be reset and access to "User menu 1" option 1 to 9.
Duress
-
Users 02-31 can be programmed as "Duress". When this user type is
entered a silent "Panic Alarm" (i.e., Bell and sounders not triggered) is
transmitted to the central station via the telephone line and remote
signalling device (if fitted). The user will still be able to set and unset the
alarm system and access "User menu 1".
Note: All other user code types will generate a "Duress" alarm if the
passcode is entered with the first two digits reversed (e.g., for a
standard passcode of 2580 enter 5280 to generate a "Duress" alarm).
If required, this feature can be disabled by the installation company or
by making the first two digits of the passcode the same.
PA Code
-
Users 02-31 can be programmed as "PA Code". When this user type is
entered a "Panic Alarm"' is transmitted to the central station via the
telephone line and remote signalling device (if fitted). The external
sounder(s) and strobe light(s) are also activated.
Access
-
Users 02-31 can be programmed as "Access". When this user type is
entered any output that is programmed as `Access' will activate for a
pre-set time. Normally this user type is used in conjunction with an
electric door strike connected to the alarm system so that when the
passcode is entered the door strike is operated to allow the user
access into that area.
Full Set Group
-
Users 02-31 may be programmed as "Full Set Group". This user type
only allows the wards assigned by the installation company or master
user to be set and unset. This user type does not have access to any
user menus.
Code Set Group A
-
Users 02-31 can be programmed as "Code Set Group A". This user type
only allows the wards assigned by the installation company or master
user to be set and unset. This user type does not have access to any
user menus.
Code Set Group B
-
Users 02-31 can be programmed as "Code Set Group B". This user type
only allows the wards assigned by the installation company or master
user to be set and unset. This user type does not have access to any
user menus.
Code Set Group C
-
Users 02-31 can be programmed as "Code Set Group C". This user type
only allows the wards assigned by the installation company or master
user to be set and unset. This user type does not have access to any
user menus.
26
User Menu 2 TS790+ & TS900+ User Manual