LCD Starburst LED Description
PA ALARM 01-56
PA.ALM 01-56
PA.01-56
Panic Alarm circuit activated.
PA CODE 01-31
PANIC 01-56
PC.01-31
Panic Alarm passcode entered.
PANEL LID TAMPER
LID TAMP
LT
Control panel lid removed.
PART SET A/B/C
P.SET A/B/C
PS.A/B/C
System Part-Set using one of the A, B, or C buttons.
PASSCODE 00-31
USER 00-31
Ur.00-31
User passcode entered. (00-31).
REMOTE ADDED 01-04
R. ADD 01-04
RA.01-04
Remote Keypad added to the system.
REMOTE RESET
REM RST
rc
System reset by “Remote Reset” passcode.
REM REMOVED 01-04
R. REM 01-04
rr.01-04
Remote Keypad removed from system.
REM SERVICE CALL
R.S. CALL
SC
Remote service call via “Lineload” software and PC.
REM TAMPER 01-04
R. TMP 01-04
rT.01-04
Remote Keypad cover removed.
SERVICE CALL END
R.S. END
SE
Remote service call finished.
SERVICE REQUIRED
SERVICE
rS
Service required
SET FAIL
SET FAIL
SF
System failed to Set.
SET WARD A/B/C/S
W. SET A/B/C/S
ST.ABCS
Wards A, B, C or System Set.
SYSTEM OPEN
SYS OPEN
OP
System fully unset.
SYSTEM RE-ARMED
RE-ARMED
rA
System re-armed all healthy circuits.
SYSTEM SET
FULL SET
FS
System fully set.
TAMPER 01-56
TAMP'R 01-56
TA.01-56
Tamper alarm from circuit.
TEST CCTS OFF
TEST OFF
To
All circuits taken off “Test”
TEST FAIL 01-56
T. FAIL 01-56
TF.01-56
Circuit failed during “Test”.
TIME CHANGED
TIME CHG
Tc
System time changed
UNSET WARD A/B/C/S
UNSET A/B/C/S
Un.ABCS
Wards A, B, C or System Unset.
WALK TEST
WALK TST
cT
System “Walk Test” selected.
Table 1b Log event codes and descriptions
Remote Call Back - 0
If your alarm system has been fitted with a modem, the installation company can dial into the
system and remotely read and write data from the control panel. For added security the
installation company can also program your alarm system so that a master user has to authorise
any write commands. When "Remote Call Back" is set to "Enabled" the installation company can
dial into the system at any time and read and write data from the control panel. When "Remote
Call Back" is set to "Disabled" the installation company can dial into the system at any time and
only read data from the control panel. Once a master user has enabled "Remote Call Back" the
system will automatically disable "Remote Call Back" after four hours.
1. Ensure that “User menu 2" is selected.
Press 0 to select the Remote Call Back
option. The display will show:
2. Press B to toggle between Enabled
(Yes) and Disabled (No). Press [ to update
with new setting or press ] abandon this
option and return to “User menu 2".
33
TS790+ & TS900+ User Manual User Menu 2
Remote Call Back
Enabled
YES
YES